THERMAL OIL HEATER      

            HEAVY-DUTY HEATERS FOR THERMAL OIL

 



 


 
QUICK
ENTRANCE

Types VTO & ELVTO
Net Capacities 23 - 10.000 kW
Operating Temperatures Standard applications up to 300°C
Special applications up to 400°C
Operating Pressures Atmospheric (Open System)
Energy Source
(Fuel)
N-gas, LPG, bio-gas, light and heavy fuel oil, combinations hereof, - and electricity (electrical heating).
Efficiencies
(Utilisation of Energy)
86 - 90% *   (based on LCV)
92 - 96% ** (based on LCV)
The Product General Description
The System General Introduction
General Sketch Horizontal & Vertical
Data & Dimensions Tables
Circulation Pumps Data & Sizes
Chimney / Flue Gas Outlet Design & Lay-out
Flue Gas Data Data & Calculations
Heat Recovery Features 'Economizers' (Flue Gas)
Alternative Type  / 1 Classic Steam Boilers
Alternative Type  / 2 Compact Steam Generators
Thermal Oil Introduction ABCO NF (Heat Transfer Fluids)
Thermal Oil Table

 *    Without Economizer
      (basic efficiency of the proposed boiler design - can be modified)
 **  Including Economizer
      (extra flue gas cooling - for instance for water heating)

The efficiencies generally depend on the actual working loads and thermal oil operating temperatures. Special designs with extreme high efficiencies can be provided on request - including special economizer solutions.

Thermal Oil Boiler  |  Thermal Fluid Boiler  |  Hot Oil Unit


 


 


AB&CO · TT BOILERS
are a well-known Danish manufacturer of thermal oil heaters, who are general specialised in customised small and medium-size industrial boilers.

Water and steam are typically used as heat carriers in heating systems. But at high temperatures, water and steam requires a corresponding high operating pressure. In thermal oil heaters, a special oil is used instead and it means that you can achieve operating temperatures up to 300°C at atmospheric pressure.

TT BOILERS Thermal Oil Heaters, type VTO & ELVTO are special designed thermal oil units, respectively with fuel oil /gas-burner - or as electrical heated units.



  inquiry data sheet

 company introduction

 

main menu          contact
 

 

 

 

 

DETAILED DESCRIPTION & SPECIFICATIONS
 

INTRODUCTION

T
T BOILERS Thermal Oil Heaters (also called Thermal Oil Boilers, Thermal Fluid Boilers or Hot Oil Units) are developed and designed especially for demanding process heating  operations where no compromise on quality are accepted and where reliablity is the key word.

The solutions comprising TT BOILERS are not based on low purchase price - the heaters are developed to ensure low over-all costs including low maintenance and operational costs
.

Consequently the TT BOILERS heaters are made of first class material and component, without any compromise on quality. The pressure part are designed as standard between 10 bar and up to 40 bar pressure (although operation often are atmospheric and pressureless).

The heaters for thermal oil (heat transfer fluid) are delivered as complete and fully equipped units with all necessary armatures, instrumentations and safety features.

The thermal oil heaters are delivered as oil-fired, gas-fired, for dual fuel and electrical heated. Other customised options are numerous and include free choice between the horizontal or vertical type. Designed for minimum 10 bar pressure with capacities in normal range up to 3000 kW, - and up to 10.000 kW on request.

 

THE BENEFITS OF USING  THERMAL FLUID

Water and steam are typically used as heat carriers (heat transfer fluid) in heating systems. But at high temperatures which is often required in process heating systems, water and steam requires a corresponding high operating pressure. Consequently high temperature heating systems with water and steam can be very controversial and expensive - both in relations to personal safety issues, economy, design and
projecting. Read more about this here.

In thermal oil heaters, a special oil-based fluid is used instead of steam or water as the heat carrier. With this oil it is quite simple to achieve operating temperatures up to 300°C at atmospheric pressure. Comparing to water and steam, this would require a pressure above 85 bar to obtain this temperature.

 

There are several advantages by using thermal oil compare to e.g. steam systems. The most obvious are:

 

   High temperatures up to 300°C at atmospheric pressure
Optional temperature level set-points
No pre-treatment of boiler feed water
No heat loss due to hot condensate and flash steam
No risk of corrosion and no risk of freezing damages.
   Low maintenance costs
   Quiet in operation (no steam stroke and flash steam noise)
   Easy to operate (does not require
steam boiler certified staff)

 

Why thermal fluid
instead of steam ?


Read more about this important issue.

 

EXTENT OF DELIVERY

The thermal
oil heaters can be delivered in horizontal design (with low height), or in vertical design (occupying limited floor space).

See the sketches below.

The heater units are delivered thermal insulated and with heat shields. The enclosure is stainless steel cover sheets. The unit design includes burner (or electrical heating elements), armatures, instrumentation, safeties and control panel - and with full documentation including the necessary certificates.

Accessories can be chosen in order to complete the thermal oil heating system. Many of these accessories can be build on a complete skid-mounted unit  - or the can be build into a container-solution.

AB&CO · TT BOILERS also deliver complete thermal fluid heating systems (read more about the system solutions in column on the right column).

 

SPECIAL DESIGNS

Beside the standard execution, the heaters type VTO and ELVTO can be delivered in e.g. following variations:

   Electrical heated and EX-design (ATEX)
   Flue gas heated
   Steam heated
   Combination of heat sources
   Container-solutions
   Skid-mounted units
   Complete heating systems
   Parts made in stainless steel
   Customised design - special requests

 

CONSTRUCTION

The oil/gas-fired heaters are made with the internal tube coils of PED certified steel tubes. The thermal
oil is heated gradually to the operational temperature during the circulation inside the tube of these tube coils - and the heat is transferred to the thermal oil first as radiant heat in the combustion chamber, where the inner cylindrical tube coil and a flat tube coil forms the chamber wall and the bottom respectively. Consequently refractory concrete is avoided. Secondly the thermal oil is heated further by the combustion gasses (which are hereafter cooled). This is done in the outer convection part, as the gasses pass the space gab between the two tube coils. The thermal design ensures a modest volume of the thermal oil relative to the size of the heater, and this allows unlimited thermal expansion due to the high fluid temperature. The heater and the thermal oil heating system in whole are constructed and equipped according DIN 4754. Pressure vessels are made according the European regulations including PED and according to all relevant EN norms.

 

vtococu2.jpg (21180 bytes)

Container Solutions - closed type container
 


Container Solutions - open type container


The electrical heated thermal oil heaters are build-up as a battery of one or several pressure vessel modules equipped with with conventional tube type or pull-out ceramic heating elements.
 

Henning_G_VTOsyst2.jpg (40529 bytes)

Skid-mounted Unit - Electrical heated


The electric thermal oil heaters type ELVTO are not only designed as heaters, they are also calculated and designed as heat exchangers involving for each project individual transfer and flow calculations on the heat surfaces.

All thermal oil heaters are carefully checked, controlled and function tested prior to dispatch from the workshop.
 

 

BURNERS & ELECTRIC HEATING ELEMENTS

The oil/ and gas-fired thermal
oil heaters are equipped  only with international recognized and high quality burner brands - adapted to operation on natural gas, light fuel oil, heavy fuel oil or combinations (dual fuel). Individual demands for special burner designs can be meet and adapted in the heater design - for instance burners for combustion of bio-gas and other low caloric or even corrosive fuel gasses.

The electrical heated units are delivered in two options. The conventional electrical tube heating elements are used typically for low temperature applications and the costs for these are correspondingly low. The electric thermal oil heaters type ELVTO, the elements are especially designed for demanding tasks which means a.o. using the special and extreme high temperature resistant Incoloy 825 alloy.

For other applications, low and easy maintenance might be an important demand. In that case it can be recommended to use full welded steel tube, where the inner heating wires place in ceramic elements can be pulled out, without emptying the heater for oil.

The engineers at AB&CO · TT BOILERS calculate the optimum heat load in the heater individually i.e. for each task, - ensuring that the film temperature of the thermal oil is never exceeded  even during stop and start.

Safe High Temperature Application
Skid-mounted Unit - Gas-fired

FLUE GAS COOLERS - ECONOMISERS

Whenever it might not be possible to use electrical heating using electricity from wind power, nuclear power or water power, - the environmental challenge is to use oil and gas-fired solutions, but at the same time to reduce the fuel consumption and thus the emission.

In this context the low flue gas temperatures  are the key words. The heat recovery is done by utilisation of  the quite large amount flue gas heat in flue gas coolers also known as  economisers. AB&CO · TT BOILERS offers complete systems that involves high efficiencies and at the same time very low pay-back times.
 

 

Economisers can be delivered as build-on to the oil or gas-fired heater, for heating external colder fluid e.g. water. Alternatively the thermal oil heater can be made as a flue gas heat exchanger - a recuperator where the external heat source is hot flue gas.

 

CO2-REDUCTION, HEAT RECOVERY
AND OTHER ENVIRONMENTAL ISSUES

Heat recovery - for instance as described above - and other environmental considerations have always been a standard topic at AB&CO, long before these became a official worldwide protocol. A lot of money is available by thinking "green". For that reason AB&CO offers consultant services. This offered arrangement has become very popular worldwide. See more about this at AB&CO · CONSULT.


 

THE HEAT TRANSFER FLUID - THERMAL OIL

The circulating heat transfer fluid, also known as the thermal thermal oil needs to be correct chosen. Compromise on this issue can easily result in huge problems - but economical and with respect to ensure personal safety. It cannot be emphasized strong enough how fatal bad, old and and inappropriate thermal oil can be for the thermal fluid heating system.

Use a quality brand of thermal oil and make sure that this fluid correspond how the heating system is operated.

An important maintenance detail is that every 6 - 12 months, a sample should be taken from the system and send to a qualified laboratory (make sure that they know about thermal fluid systems and what traces they should look for in the sample) or directly to AB&CO.

Due to this important issue, AB&CO has established a department dealing with thermal fluid supply and sample analysis:

It is recommended to use a non fouling, high temperature resistant thermal oil for the applications like AB&CO NF. This fluid is available at our stock in Copenhagen.

 

 

THERMAL OIL SYSTEM SOLUTIONS

A correct and safe system design is very important for high temperature systems. This can be ensured by using
AB&CO · TT BOILERS as system supplier of the whole system. The engineers of AB&CO · TT BOILERS will design the heating system in a close dialog with the customer and/or the contractors. Visits on site can be provided in connection with kick-off meeting, commissioning and start-up.

AB&CO · TT BOILERS has 20 years experience with thermal oil heating (hot oil) solutions world-wide - both new installations or modified systems.

Complete
hot oil heating systems with heaters, heat exchangers, tanks, pumps, armatures, instrumentations and piping can be delivered as package solutions and as skid-mounted units - individually designed according DIN4754.


 




main menu


contact

Dimension Sketches
wpeA.gif (11196 bytes)

Type VTO

[kW]

Heat
Capacity
[Mcal/h]

A

[mm]

B

[mm]

C

[mm]

D

[mm]

E

[mm]

F

[mm]

Weight
Empty
[kg]

Weight
Service
[kg]

70 60 1800 1500 1300 1000 1400 ø150 400 450
140 120 2600 2100 1300 1100 1500 ø150 500 600
235 200 2700 2300 1500 1200 1550 ø210 650 800
350 300 3300 2700 1600 1200 1600 ø210 1000 1200
600 520 3700 3000 1800 1350 1800 ø355 1700 2200
1000 860 3900 3200 2300 1700 2300 ø400 2400 3200
1500 1300 4300 3600 2500 1950 2800 ø500 3600 4800
2000 1720 4800 5100 2600 2100 2900 ø560 4000 5500
2350 2000 5300 4600 2800 2200 3100 ø560 4300 5800
2750 2365 5400 4700 2900 2300 3300 ø630 4500 6600
3000 2580 5500 4800 3000 2400 3400 ø630 4800 6900
3500 - 10000 3000 - 8600

On request


main menu          contact